Background Image
Table of Contents Table of Contents
Previous Page  376 556 Next Page
Information
Show Menu
Previous Page 376 556 Next Page
Page Background

376

LIGHTING SOLUTIONS

Industrial

CA452001EN - March 2015

Hazardous Area Luminaires

Lamp and Control Gear Options

• 18W, 36W, 58W T8 fluorescent

• 11W PL-L fluorescent

• LED (Exit and Exit N only)

• High frequency control gear as standard

Materials

• Body - eLLK/eLLM/nLLK - Glass fibre reinforced polyester

• Diffuser - eLLK/eLLM/nLLK - Polycarbonate

• Housing - eLLB/D-RLF250 - Steel, white powder coat finish

• Protective cover - eLLB/D-RLF250 - 6mm/5mm thick safety

glass

• Exit housing and lens - EXIT LED - Polycarbonate

• Enclosure - EE 11 - Copper-free Aluminium

• Protective cover - EE 11 - Borosilcat-Glass

Installation Notes

• eLLK: Double sided tooled access mechanism also allows

diffuser to hang for ease of maintenance

• eLLK: Through wiring facility

• eLLK/nLLK are surface mount luminaires

• eLLM are post mount luminaires, 44mm dia pole socket in

the housing

• eLLB/D-RLF are recessed luminaires

• EXIT LED bulkheads are mains powered luminaires the EXIT N

LED versions are self contained emergency versions

• Where emergency converted fluorescent versions do not state

the emergency duration they can generally be selected as 1.5

or 3 hour duration upon installation

• Fluorescent supplied less lamp

Options

• Fully integral emergency conversions, 1.5 or 3 hour duration

(not available on 58W T8)

• Emergency with CEAG CG-S module for central battery

operation and monitoring available on some models

Photometric Data

• Refer to the website for luminaire photometric data, available in

ldt and IES formats

• Enter the catalogue reference in the keyword search on the

homepage:

www.coopercrouse-hinds.eu

Certification

• Refer to the website for luminaire certification of the specific

catalogue reference selected

• Enter the catalogue reference in the keyword search on the

homepage:

www.coopercrouse-hinds.eu

Dimensions

• Refer to the website for dimensions of the specific catalogue

reference selected

• Enter the catalogue reference in the keyword search on the

homepage:

www.coopercrouse-hinds.eu

Catalogue Numbers

Part Number Description

Lamp Emergency

Rating

Duration

Zone I: eLLK 92 Series Fluorescent Light Fittings

12265875111 Zone 1 eLLK 92018/18 2/6-2M luminaire 2x18W HF

2 x 18W -

12266875111 Zone 1 eLLK 92036/36 2/6-2M luminaire 2x36W HF

2 x 36W -

12267875111 Zone 1 eLLK 92058/58 2/6-2M luminaire 2x58W HF

2 x 58W -

12260879111 Zone 1 eLLK 92018/18 Nib 2/6-2 M Emergency luminaire 2x18W HF

2 x 18W 1.5 or 3 hour

12261879111 Zone 1 eLLK 92036/36 Nib 2/6-2M Emergency luminaire 2x36W HF

2 x 36W 1.5 or 3 hour

Zone I: eLLM 92 Series Pole Mounted Fluorescent Fittings

12268875101 Zone 1 eLLM 92018/18 Pole Mount Luminaire 2x18W HF

2 x 18W -

12269875101 Zone 1 eLLM 92036/36 Pole Mount Luminaire 2x36W HF

2 x 36W -

12273879101 Zone 1 eLLM 92018/18 Nib Pole Mount Emergency Luminaire 2x18W HF

2 x 18W 3 hour

Zone I: eLLB 20 Series Recessed Fluorescent Fittings

12190218101 Zone 1 eLLB 20018/18 2/6-2 M Recessed Luminaire 2x18W HF white painted housing

2 x 18W -

12190236101 Zone 1 eLLB 20036/36 2/6-2 M Recessed Luminaire 2x36W HF white painted housing

2 x 36W -

12190258101 Zone 1 eLLB 20058/58 2/6-2 M Recessed Luminaire 2x58W HF white painted housing

2 x 58W -

12190218102 Zone 1 eLLB 20018/18 Nib 2/6-2 M Recessed Emergency Luminaire 2x18W HF white painted housing 2 x 18W 3 hour

12190236102 Zone 1 eLLB 20036/36 Nib 2/6-2 M Recessed Emergency Luminaire 2x36W HF white painted housing 2 x 36W 3 hour